Gas, water quality & more
Backflow testing and repair in Aurora, CO
A backflow preventer is the device that keeps sprinkler water, fertilizer and lawn runoff from being pulled back into your drinking water. Aurora requires those assemblies to be tested every year, and we test, repair and rebuild them so yours passes.
SERVICE PLATE
- Service
- Backflow Testing & Repair
- Typical range
- $85 to $165
- Area
- Aurora and the east metro
- Hours
- Answered 24/7
- Phone
- (720) 894-1012
Brands we work on every week
Yes, Aurora requires testable backflow prevention assemblies to be tested before the property is occupied and at least once a year after that, with results reported to Aurora Water. For most homeowners that means the sprinkler backflow preventer. Spring start-up is when most owners schedule it, and a failed test usually means a cleaning or a repair kit.
What a backflow test actually measures
Backflow happens when pressure in the city supply drops, from a main break or heavy firefighting draw, and water in your pipes reverses direction. Without protection, water sitting in sprinkler lines, which can carry fertilizer, weed killer and soil bacteria, could be siphoned back toward the public system. The assembly's check valves are what stop it.
During a test we connect a differential pressure gauge to the test cocks, close the shutoffs in the right order and measure whether each check valve holds and, on reduced pressure units, whether the relief valve opens at the correct point. The numbers are recorded and either pass or fail. A test takes minutes when the device is accessible and in good shape.

When the assembly fails, here is what we fix
Most failures are mechanical and repairable. Grit lodges under a check seat, a rubber disc hardens, a spring weakens or a relief valve diaphragm tears. We isolate the device, open it up, clean the seats and install the manufacturer's repair kit. Then we retest, because only a passing result after the repair counts.
Replacement makes more sense when the body is cracked, the device is obsolete and parts are not available, or freeze damage has split a bonnet or the bronze housing. We tell you which situation you are in before any work starts, with the price for each, so you can decide whether a rebuild or a new assembly is the better buy.
Keeping the device from freezing every winter
Most homeowner backflow preventers sit outside on a riser near the foundation, where they take the full force of winter wind. When the system is shut down in fall, the isolation valve upstream should be closed, the test cocks opened and the device drained so no water is left in the body to expand and crack it.
We can do that winterizing step during a fall visit, or show you how so you can handle it yourself each year. An insulated cover over the assembly helps during an early cold snap, but it does not replace draining. A device full of water will still crack under a cover once the temperature stays low for long enough.
Warning signs
Is your backflow preventer telling you something?
Your annual test notice arrived
Aurora Water tracks testable assemblies and expects a passing test result each year. If a reminder showed up in the mail, the clock is already running on your assembly.
Water sprays from the device in spring
A backflow preventer that was not drained before a hard freeze can crack its body or split a test cock. You often discover it the first time the sprinklers come on.
Constant dripping from the relief port
On a reduced pressure assembly, a steady discharge from the relief valve usually points to debris or a worn check valve. It wastes water and won't pass a test.
Sprinkler pressure dropped suddenly
A stuck check, a partly closed shutoff or a clogged inlet screen at the assembly can starve the zones downstream. Weak heads across the whole yard point back to the device.
The assembly failed last year
If a previous tester reported a failure, the assembly needs repair and a retest. Ignoring it does not reset the requirement, and the device is not protecting your water.
You added or replaced an irrigation system
A new sprinkler system needs a properly installed assembly that is tested at installation. Replacing a device after freeze damage also calls for a fresh test.
Aurora notes
Aurora Water's backflow requirement, in plain terms
Aurora Water requires backflow assemblies on sprinkler systems to be tested, and spring start-up is when most owners schedule it. Under the city's rules, a required testable assembly gets tested before a certificate of occupancy is issued and at least once a year after that. The test must be done by a qualified cross-connection control technician, and proof of a passing test goes to Aurora Water by the annual due date. The cost is the property owner's or water customer's responsibility.
Aurora winters bring sudden arctic cold fronts and big day-to-night swings, and sprinkler backflow devices are one of the usual freeze victims. An assembly that looked fine in October can show up split in April. That is why we pair spring testing with a quick visual check of the riser, the shutoffs and the test cocks, so freeze damage gets found and fixed before the first watering day rather than after.
Step by step
What a backflow test visit includes
- 01
Locate and inspect the assembly
We find the device, note its make, model and serial number, and check the body, valves and test cocks for cracks, leaks or freeze damage.
- 02
Run the test
Using a calibrated differential gauge, we test each check valve and the relief valve where present, following the standard procedure for that assembly type.
- 03
Explain the result
A pass means you are done for the year. A failure comes with a clear explanation of what failed and a price to repair or replace the device.
- 04
Repair and retest if needed
We clean the seats, install the repair kit or replace the assembly, then run the full test again so the result on file is a pass.
- 05
Report to Aurora Water
We complete the test report with the assembly details and readings so the required results reach Aurora Water and you have a copy for your records.
Pricing
Backflow testing and repair prices in Aurora
TYPICAL AURORA PRICE RANGES
| Annual residential backflow assembly test with report | $85 to $165 |
|---|---|
| Spring sprinkler start-up with backflow test | $135 to $245 |
| Backflow assembly cleaning and repair kit with retest | $165 to $385 |
| Freeze-cracked residential assembly replacement | $385 to $865 |
| Commercial or fire line assembly test | $145 to $295 |
These are typical Aurora ranges, not a quote. The actual price depends on the assembly type and what we find when we test and open it.
- Assembly typePressure vacuum breakers, double checks and reduced pressure assemblies each test differently, and their repair kits vary in price.
- Size of the deviceResidential sprinkler assemblies are small. Larger commercial and fire line devices take longer to test and cost more to rebuild.
- Condition and accessA device buried in shrubs, set in a deep vault or seized at the shutoffs takes extra time before testing can even begin.
- Freeze damageA cracked body or bonnet cannot be rebuilt, so the job becomes a replacement with new fittings, a test at installation and a report.
Compare more jobs in our plumbing price guide.
Questions
Backflow Testing & Repair questions from Aurora homeowners
Does Aurora Water really require a backflow test every year?
Yes. Testable backflow prevention assemblies required by the city must be tested before occupancy and at least once a year after that, with passing results provided to Aurora Water by the annual due date. For most homes the assembly is on the sprinkler system, so the test usually happens at spring start-up.
What is the difference between a PVB and an RP backflow assembly?
A pressure vacuum breaker, or PVB, has one check and an air inlet, and it must sit above the highest sprinkler head. A reduced pressure assembly, or RP, has two checks with a relief valve between them and can be installed in more places. Both are testable devices that need yearly testing.
Can I test my own sprinkler backflow preventer?
No. Aurora's rules require the test to be done by a qualified cross-connection control technician using a calibrated gauge. Homeowners can help by draining the device each fall and keeping shrubs trimmed back so the tester can reach it, which makes the visit faster.
Why did my backflow preventer crack over the winter?
Water left inside the body froze and expanded. That happens when the device is not drained at shutdown, or when an early cold front arrives before winterizing. Bronze bodies, bonnets and test cocks can all split. A cracked device has to be replaced, then tested at installation.
What happens if my backflow assembly fails the test?
The tester notes which part failed. Most failures are fixed by cleaning the check seats or installing a repair kit, then retesting. Only a passing result satisfies the requirement, so we finish the repair and retest in the same visit whenever the parts are available.
Related work
Other plumbing jobs that often go with this one

Outdoor Faucet & Sillcock Repair
Leaking hose bibs and freeze-damaged sillcocks repaired or replaced with frost-free valves built for Colorado winters.
Learn more
Pipe Freeze Protection
Pipe insulation, heat cable, rerouting and winter shutdown plans that keep water lines from freezing in deep cold.
Learn more
Pressure Reducing Valves
Test, adjust or replace the valve that keeps city water pressure from hammering your pipes, fixtures and water heater.
Learn more
Commercial Plumbing
Plumbing repair and maintenance for restaurants, offices, retail spaces and multifamily buildings, with after-hours service when needed.
Learn moreCoverage
Where we do backflow testing & repair around Aurora
These neighborhoods and nearby cities cover most of the households we serve. Not listed? Call and ask.
- Original Aurora, Aurora 80010
- Del Mar, Aurora 80010
- Hoffman Heights, Aurora 80011
- Aurora Hills, Aurora 80012
- Village East, Aurora 80012
- Willow Park, Aurora 80012
- Aurora Knolls, Aurora 80012
- Heather Gardens, Aurora 80014
- Aurora 80012
- Denver 80202
- Centennial 80112
- Parker 80134
- Englewood 80110
- Littleton 80120
- Greenwood Village 80111
- Lone Tree 80124
Need help with backflow testing & repair?
Call any time, day or night. A real person answers and tells you what happens next.